CareFusion Avea Specifications
Dimensions
- Pneumatic Module: 10.5” h x 16.75” w x 16” d (26.7 cm x 43.2 cm x 40.6 cm)
- User interface Module: 13.75” h x 16.25” w x 2.5” d (35 cm x 41.3 cm x 6.4 cm)
- Viewable Size: 12.1” (diagonal)
- Resolution: 800 x 600
Weight
- Ventilator w/ UIM no Compressor: < 73 lbs. (33.1 kg)
- Ventilator w/UIM and Compressor < 80 lbs (36.3 kg)
Battery
- 1 hr of ventilator use on internal battery (standard) or 30 minutes ventilator and compressor
- 4 hr of ventilator use on external battery or 2 hr ventilator and compressor
Setup
- Humidifier: Active and passive humidification
- Circuit compliance compensation: 0.0 to 7.5 mL/cmH2O
- Leak compensation: ON, OFF
Endotracheal Tube Setup
- Diameter: 2.0 to 10.0 mm
- Length: 2.0 to 30.0 cm
- Automatic tube compensation: ON, OFF
Patient Setup
- Patient weight: 0.1 to 300 kg
- Patient ID: Alphanumeric 24 characters
Modes
- Mode type: A/C, SIMV, CPAP/PSV, NPPV, nasal CPAP/IMV
- Breath type: APRV/BiPhasic,Volume, Pressure, TCPL, PRVC,Volume Guarantee
- Apnea backup: Volume, pressure
Primary Settings
- Rate: 1 to 150 bpm (neonatal, pediatric), 1 to 120 bpm (adult)
- Tidal volume: 2.0 mL to 2.5 L
- Inspiratory pressure: 0 to 80 cmH2O (neonatal), 0 to 90 cmH2O (adult, pediatric)
- Peak flow: 0.4 to 150 L/min
- Inspiratory time: 0.15 to 5.0 sec
- Pressure support ventilation: 0 to 80 cmH2O (neonatal), 0 to 90 cmH2O (adult, pediatric)
- PEEP: 0 to 50 cmH2O
- Flow trigger: 0.1 to 20 L/min
- %O2: 21% to 100%
- Pressure high (in APRV mode): 0 to 90 cmH2O
- Time high (in APRV mode): 0.2 to 30 sec
- Time low (in APRV mode): 0.2 to 30 sec
- Pressure low (in APRV mode): 0 to 45 cmH2O
Advanced Settings
- Bias flow: 0.4 to 5.0 L/min
- Volume limit: 2.0 mL to 2.5 L
- Inspiratory rise: 1 to 9
- Flow cycle: Off to 45%
- PSV rise: 1 to 9
- PSV cycle: 5% to 45%
- PSV Tmax: 0.15 to 5.0 sec
- Waveform: Decelerating, square
- Sigh: ON, OFF
- Pressure trigge:r 0.1 to 20 cmH2O
- Demand flow: ON, OFF
- Volumetric capnography: EtCO2 averaging 1 or 8 breaths, VCO2 averaging 3, 6, 9 or 12 minutes
Manual Controls
- Manual breath: One breath
- Expiratory hold: Maximum 20 sec (adult, pediatric), 3 sec (neonatal)
- Inspiratory hold: Maximum 3 seconds
- Increase O2: Set percentage O2 + 0% to 79% O2
- Synchronized nebulizer: Available when peak flow > 15 L/min
- Disconnect for suction: Active
Advanced Gas Blending System
- Air/oxygen Blending: 21–100%
- Internal Heliox Blending System: All concentrations from 80/20 helium/oxygen to 0/100 helium/oxygen
Advanced Patient Monitoring
- Proximal hot wire flow sensor
- Proximal variable orifice flow sensor (infant, pediatric, adult)
- Proximal airway pressure monitoring
- Tracheal pressure monitoring
- Esophageal pressure monitoring
- Volumetric capnography
Maneuvers
- AutoPEEP Airway: 0–50 cmH2O (automated)
- MIP/P100: -60 to 120 cmH2O (automated)
- low Flow (Pflex): Automated
Alarms
- Vent inop Ventilator inoperative
- Loss of gas All gas sources lost
- Circuit disconnect Patient circuit disconnected
- Ext. high Ppeak High Ppeak longer than 5 seconds
- Safety valve Safety valve open
- Circuit occlusion Circuit occlusion
- High Ppeak High peak pressure
- Apnea interval Apnea interval exceeded
- Loss of O2 Oxygen supply lost
- Loss of air Air supply lost
- Loss of heliox Heliox supply lost
- Low battery Internal/external batteries low
- Loss of A/C Main AC power lost
- Low PEEP Low PEEP cmH2O
- Low Ppeak Low PIP cmH2O
- Low Vte Low tidal volume
- Low Ve Low minute volume
- Low %O2 Low FiO2 reading
- High %O2 High FiO2 reading
- ILV disconnect Independent lung ventilation lost
- Alarm test Test alarm/set loudness
- Invalid gas ID Gas type ID bad or missing
- High Ve High minute volume
- High rate High breath rate
- Max insp time Inspiratory time limit exceeded
- I:E limit I:E ratio limit exceeded
- Fan failure Cooling fan failure
- High Vt High tidal volume
- Vol limit Volume limit exceeded
- Low EtCO 3 2 Low end tidal CO2
- High EtCO 3 2 High end tidal CO2
- nCPAP pressure limit nCPAP pressure limit exceeded
- Low nCPAP pressure Low nCPAP cmH2O
- High nCPAP pressure High nCPAP cmH2O
พร้อมเครื่องสำรองใช้งาน กรณีส่งซ่อมหรือเครื่องมีปัญหา
สนใจสินค้า ต้องการสอบถามข้อมูล หรือนัดหมายเข้ามาเยี่ยมชมสินค้า ติดต่อเข้ามาได้เลยค่ะ
Tel. 098-632-9351
Line ID: 0813451047
Line : @thaimedicaltrading
Website : www.thaimedicaltrading.co.th
พร้อมบริการติดตั้ง
รับประกัน 1 ปี พร้อมทีมช่งเครื่องอแพทคอยดูแลเครื่อง และมีอะไหล่สำรอง ตลอดอายุการใช้งาน
พร้อมสอนการใช้งานอย่างถูกต้อง ติดตั้งและจัดส่งทั่วประเทศ
ขายเครื่องช่วยหายใจมือสอง,เครื่องช่วยหายใจ,ขายเครื่องช่วยหายใจ,เครื่องช่วยหายใจราคา,เครื่องช่วยหายใจราคาถูก,ขายเครื่องช่วยหายใจราคาถูก,volume control ventillator,used ventillator,refurbished ventillator,Avea Carefusion